For the complete documentation index, see llms.txt. This page is also available as Markdown.

Storing the IF1200 Batteries

This guide contains step by step instructions for placing the IF1200 batteries into storage mode, as well as recommendations for how to store the batteries to best preserve battery health.

All technical information on this page is summarized from the original battery manufacturer, Tattu. For more information, consult the Tattu-Plus 1.0 Manual Linked Below.

Manufacturer Smart Battery Manual

Storage Recommendations

Short Term Storage

The ideal voltage to store the IF1200 batteries at is 3.90V, or between 40 ~ 70% charge. Storing the batteries within this range will extend the life of the batteries.

If the IF1200 batteries are fully charged (or above 3.90V), and remain unused for 5 days, they will initiate an automatic discharge process down to 3.90V (between 40 ~70%). The automatic discharge process will heat up the batteries.

Long Term Storage

It is recommended to cycle charge (charge and discharge to storage voltage) the batteries every 3 months to ensure the best service life of the batteries.

Shipping

If a battery is getting shipped, it is recommended to put the battery in Storage Mode. This will charge or discharge the battery to the optimal storage voltage. See Placing Batteries Into Storage Mode.

Storage Safety

Placing Batteries into Storage Mode

  1. Find a clear space with ample room to place down the charger and batteries.

  1. Plug the power cable into the back of the charger, and the other end into a wall outlet or power strip.

The charger does not have a power button, and will turn on automatically when it receives power. Because of this, it is recommended to plug the charger into a dedicated power strip to easily switch the charger on and off.

  1. Before plugging the battery into the charger, press the red power button and confirm the battery power on with no triangluar error LEDs present.

  1. Ensure that the balance cable is plugged into Balance Port A as shown.

  1. Plug the other end of the balance cable into the battery.

Note that the white connector on the balance cable is not used.

  1. Plug the yellow connector on the battery into Charge Port A.

  1. Repeat steps 3-5 for Channel B.

  1. Once both batteries are plugged in, press the current button to cycle through currents. It is recommended to set this to 16A, as that is the 1C charging rate for 16000mAh batteries.

  1. Press the Mode button to cycle between modes until Storage mode is selected.

  1. Press and hold the Start/Stop button to initiate the storage process.

  1. Once the batteries are finished charging or discharging to storage voltage and display a Complete or Idle state, it is safe to unplug both batteries.

Last updated